Journal of Systems Engineering and Electronics
• RELIABILITY • Previous Articles
Jiarong Liang*, Ying Huang, and Liangcheng Ye
Online:
Published:
Abstract:
The exchanged hypercube EH(s, t) (where s ≥1 and t ≥1) is obtained by systematically reducing links from a regular hypercube Qs+t+1. One-step diagnosis of exchanged hypercubes which involves only one testing phase during which processors test each other is discussed. The diagnosabilities of exchanged hypercubes are studied by using the pessimistic one-step diagnosis strategy under two kinds of diagnosis models: the PMC model and the MM* model. The main results presented here are the two proofs that the degree of diagnosability of the EH(s, t) under pessimistic one-step t1/t1 fault diagnosis strategy is 2s where 1 ≤ s ≤ t (respectively, 2t, where 1 ≤ t ≤ s) based on the PMC model and that it is also 2s where 1 ≤ s ≤ t (respectively, 2t, where 1 ≤ t ≤ s) based on the MM* model.
Jiarong Liang, Ying Huang, and Liangcheng Ye. Diagnosabilities of exchanged hypercube networks under the pessimistic one-step diagnosis strategy[J]. Journal of Systems Engineering and Electronics, doi: 10.1109/JSEE.2015.00048.
0 / / Recommend
Add to citation manager EndNote|Reference Manager|ProCite|BibTeX|RefWorks
URL: https://www.jseepub.com/EN/10.1109/JSEE.2015.00048
https://www.jseepub.com/EN/Y2015/V26/I2/415