Journal of Systems Engineering and Electronics ›› 2009, Vol. 20 ›› Issue (4): 762-767.

• SYSTEMS ENGINEERING • Previous Articles     Next Articles

Super-resolution processing of passive millimeter-wave images based on conjugate-gradient algorithm

Li Liangchao, Yang Jianyu, Cui Guolong, Wu Junjie, Jiang Zhengmao & Zheng Xin   

  1. School of Electronic Engineering, Univ. of Electronic Science and Technology of China, Chengdu 610054, P. R. China
  • Online:2009-08-14 Published:2010-01-03

Abstract:

This paper designs a 3 mm radiometer and validate with experiments based on the principle of passive millimeter wave (PMMW) imaging. The poor spatial resolution, which is limited by antenna size, should be improved by post data processing. A conjugate-gradient (CG) algorithm is adopted to circumvent this drawback. Simulation and real data collected in laboratory environment are given, and the results show that the CG algorithm improves the spatial resolution and convergent rate. Further, it can reduce the ringing effects which are caused by regularizing the image restoration. Thus, the CG algorithm is easily implemented for PMMW imaging.